Symptoms
- Engine runs smoothly but nothing plugged in gets power
- No voltage reading at the outlets with a meter
- Worked fine before, then suddenly no output
- Some outlets work, others don't
Likely causes
- CommonTripped internal circuit breakerOverloading or a short can trip a breaker on the panel that's easy to overlook.
- CommonGenerator lost residual magnetism (common after long storage)Conventional generators need a small residual magnetic field to begin generating; long periods unused can let this fade, a process called 'flashing the field' can restore it.
- PossibleBad GFCI outlet on the generator itselfMany portable generators have built-in GFCI outlets that can trip or fail, cutting power to just those receptacles.
- PossibleFaulty AVR (automatic voltage regulator)This component regulates output voltage; failure can cause zero or very low output.
- PossibleBlown fuse or failed capacitor inside the generator headEspecially relevant on inverter generators, which use more electronics.
What to do
- Check and reset any tripped breakers on the generator's control panel.
- Reset any GFCI outlets on the generator itself by pressing their reset button.
- Test a single, known-good device (like a work light) directly at each outlet with the engine at operating speed.
- Use a multimeter at the outlets to check for any voltage output, even low, which helps distinguish a total failure from a regulation problem.
- If the generator hasn't been used in a long time and shows zero output, look up your model's 'residual magnetism' or 'flashing the field' procedure in the owner's manual, since this is a known issue on some conventional generators.
- Check the owner's manual for an accessible fuse related to the outlets or control panel and inspect it.
- If none of this restores output, the AVR or generator head likely needs professional testing and possible replacement.
Tools and parts
- Multimeter
Automatic voltage regulator (AVR)Search: “generator AVR replacement”
When to call a pro
If breakers, GFCIs, and basic checks don't restore output, have a small-engine or generator repair shop test the AVR and generator head.
Safety
Use caution
Never work inside a running generator's electrical components; shut it off and let it cool before any internal inspection.