Symptoms
- Pilot lights but goes out within seconds of releasing the knob
- Repeated relighting doesn't help
- No heat because the pilot keeps dying
Likely causes
- CommonDirty or misaligned thermocoupleThis safety sensor must sit directly in the pilot flame to register it and keep gas flowing.
- CommonWeak or failing thermocoupleThermocouples wear out over years and stop holding the valve open even when clean.
- PossibleDraft blowing out the pilot flameAirflow from a nearby vent or door can extinguish a small pilot flame.
- PossibleDirty pilot orifice restricting gas flowA partially clogged orifice produces a weak flame that won't heat the thermocouple enough.
- Less commonFaulty gas valveThe valve itself can fail and stop supplying gas properly to the pilot.
What to do
- Turn the gas control knob to Off and wait 5 minutes for gas to clear before doing anything else.
- Follow the lighting instructions printed on the furnace panel exactly, holding the pilot knob in as directed.
- Hold the knob in for the full time listed (often 30–60 seconds) before releasing so the thermocouple heats fully.
- If it goes out immediately when released, the thermocouple is likely dirty; let it cool and gently clean it with fine sandpaper or a cloth.
- Check that the thermocouple tip sits directly in the blue part of the pilot flame, not off to the side.
- If cleaning doesn't help, the thermocouple has likely failed and needs replacement, which is an inexpensive part.
- Never bypass the thermocouple or hold the gas valve open manually to force the pilot to stay lit.
Tools and parts
- Fine sandpaper or emery cloth
- Flashlight
Furnace thermocoupleSearch: “universal furnace pilot thermocouple replacement”
When to call a pro
Call a technician or your gas utility if the pilot still won't hold after cleaning the thermocouple, or if you ever smell gas.
Safety
Use caution
You're working around live natural gas; always follow the shutoff and wait steps before relighting, and stop and call the gas utility if you smell gas.