Symptoms
- Lights connected to the generator are dim or unusually bright
- A multimeter reading at the outlet is well off from 120V
- Electronics behave oddly or shut off when running on generator power
- Engine speed sounds too slow or too fast compared to normal
Likely causes
- CommonEngine running at the wrong speed (RPM)Output voltage and frequency are directly tied to engine RPM; a governor issue or wear can throw this off.
- CommonOverloaded generator dragging voltage downAsking for more power than rated causes voltage to sag under load.
- PossibleFailing automatic voltage regulator (AVR)This component actively regulates output; failure can cause voltage well outside normal range.
- PossibleWorn brushes (on brushed generator heads)Worn brushes reduce the excitation needed for proper voltage regulation.
What to do
- Reduce the connected load to well under the generator's rated capacity and see if voltage returns to normal.
- Check the engine's idle/running speed against the manufacturer's spec (most are set for 3600 RPM for 60Hz output) using a tachometer if available.
- Inspect and adjust the governor linkage if the engine speed is clearly off from spec.
- Measure output voltage at an outlet with a multimeter, both unloaded and with a light load, to see how far off it is.
- If speed and load are both fine but voltage is still wrong, suspect the AVR.
- On brushed generator heads, check brush wear and replace if worn short.
- Persistent wrong voltage after ruling out speed and load issues should be diagnosed by a generator repair shop, since running equipment on bad voltage can damage it.
Tools and parts
- Multimeter
- Tachometer (if available)
Generator AVRSearch: “generator automatic voltage regulator”
Generator brushesSearch: “generator head carbon brushes”
When to call a pro
Have a generator repair shop diagnose voltage problems that persist after checking load and engine speed, since incorrect voltage can damage connected equipment.
Safety
Use caution
Don't run sensitive electronics on a generator you suspect is producing incorrect voltage until it's diagnosed.