Furnaces & heating

Gas fireplace pilot won't stay lit

Just like a furnace, this is almost always a worn or dirty thermocouple failing to sense the flame and hold the gas valve open.

Difficulty
Moderate
Time
20–30 minutes
DIY cost
$10–$30
Pro cost
$100–$200

Symptoms

  • Pilot lights but goes out once the button or knob is released
  • Repeated attempts to relight don't help
  • No heat because the main burner never gets a chance to ignite

Likely causes

  • CommonDirty or misaligned thermocoupleThe sensor needs to sit directly in the pilot flame to keep the gas valve open.
  • CommonWorn-out thermocoupleThese wear out over years of use and eventually can't hold the valve open even when clean.
  • PossibleDraft from a nearby vent or door blowing out the flameA drafty room can extinguish a small pilot flame repeatedly.
  • PossibleWeak pilot flame from a partially clogged orificeDust or debris can restrict gas flow enough to weaken the flame.

What to do

  1. Follow the printed lighting instructions, holding the pilot control in for the full specified time (often 30–60 seconds).
  2. Check that the pilot flame is a strong, steady blue, not small, yellow, or flickering.
  3. Confirm the thermocouple tip sits directly in the pilot flame; adjust gently if it's visibly off to the side.
  4. With the gas off and the assembly cool, clean the thermocouple tip with fine sandpaper if it looks dirty.
  5. Close nearby doors or windows to rule out a draft blowing the pilot out during your test.
  6. If cleaning doesn't help, the thermocouple likely needs replacement, which is a straightforward part for a technician.

Tools and parts

  • Fine sandpaper
Fireplace thermocoupleSearch: “gas fireplace thermocouple replacement”

When to call a pro

Call a gas fireplace technician if the pilot won't hold after cleaning, or to replace a worn thermocouple.

Safety

Use caution

Always wait the full clearing time before relighting and stop immediately if you smell gas.