Gas ranges

Dedicated simmer burner still burns too hot

If a range's special low-simmer burner won't go as low as expected, it's usually a valve or orifice issue specific to that burner's design.

Difficulty
Easy
Time
15–25 minutes
DIY cost
$0–$25
Pro cost
$100–$200

Symptoms

  • Simmer burner still scorches or boils delicate sauces
  • Other standard burners simmer fine at their lowest setting
  • Simmer burner may have a different-looking cap or grate marking
  • Problem is consistent every time you use it

Likely causes

  • CommonSimmer burner valve out of adjustmentThese burners rely on a precisely calibrated low-flow valve that can drift.
  • PossibleIncorrect or swapped burner cap on the simmer positionUsing a standard burner's cap on the simmer position changes its output.
  • PossibleClogged simmer burner orificeEven a slight clog can push a naturally low-flow burner higher than intended.
  • Less commonSimmer valve failureThe specialized valve mechanism can fail over time.

What to do

  1. Confirm the correct, dedicated cap is on the simmer burner position, checking your manual's diagram if unsure.
  2. Clean the simmer burner head and cap thoroughly, since this burner is more sensitive to small clogs given its low output.
  3. Test again after cleaning and reseating the correct cap.
  4. Compare its lowest flame size to what your manual describes as normal for that burner.
  5. Do not attempt to adjust the simmer valve yourself, since it's a factory-calibrated part.
  6. If it still won't simmer low enough after cleaning, have a technician inspect or adjust the simmer valve.

Tools and parts

  • Soft brush
Simmer burner capSearch: “range simmer burner cap replacement”

When to call a pro

If cleaning and confirming the correct cap doesn't help, a technician can inspect or adjust the simmer burner's valve.

Safety

Generally low risk

Generally low risk for a careful person. Stop if anything looks different from what this guide describes.